Home Products

single hinged expansion joint

Certification
China Jiangsu Qianyuanfeida  electric equipment Co.,Ltd certification
China Jiangsu Qianyuanfeida  electric equipment Co.,Ltd certification
I'm Online Chat Now

single hinged Expansion Joint

SS Material Hinged Type Plumbing Expansion Joint , Pipe Bellows Expansion Joint

  • SS Material Hinged Type Plumbing Expansion Joint , Pipe Bellows Expansion Joint
  • SS Material Hinged Type Plumbing Expansion Joint , Pipe Bellows Expansion Joint
  • SS Material Hinged Type Plumbing Expansion Joint , Pipe Bellows Expansion Joint
  • SS Material Hinged Type Plumbing Expansion Joint , Pipe Bellows Expansion Joint

Hinged type expansion joint with welding ends ISO 9001 certification

 

Product description

 

Hinged bellows expansion joints are mainly used in various complicated piping systems to compensate the angular displacement of piping systems, such as L-shaped pipes, Z-shaped pipes, U-shaped pipes, etc.Widely used in petroleum, chemical industry, steel, metallurgy, machinery, transportation, transportation, shipbuilding, dock, construction, rubber, papermaking, textile, electric heating network, pharmaceutical, medical and other industries.

 

Features

 

The hinge-type corrugated expansion joint absorbs the angular displacement caused by thermal expansion or contraction along the axial direction of a pipeline, a conveying channel or a container through a change in its angle.Usually two or three pieces are used in combination. The compensation amount is proportional to the distance between the two products. Its advantages are small size and light weight. The pressure thrust of the product is borne by the hinge member. The angular hinge ripple compensator can compensate the pipeline in any direction.Angular displacement.

 

Installation

 

1. The hinge type corrugated compensator should be checked for its model, specifications and pipeline configuration before installation. It must meet the design requirements.

 

2. For the compensator with inner sleeve, care should be taken to make the direction of the inner sleeve consistent with the medium flow direction. The hinge rotation plane of the hinge type compensator should be consistent with the displacement rotation plane.

 

3. A "cold tight" compensator is required. The auxiliary components used for pre-deformation should be removed after the pipeline is installed.

 

4. It is strictly forbidden to use the method of deformation of the corrugated compensator to adjust the installation tolerance of the pipeline, so as not to affect the normal function of the compensator, reduce the service life and increase the load of the piping system, equipment and support members.

 

5. During the installation process, the welding slag is not allowed to splash on the surface of the wave shell, and the wave shell is not allowed to be damaged by other machinery.

 

6. After the installation of the piping system, the yellow auxiliary positioning components and fasteners used for installation and transportation on the corrugated compensator should be removed as soon as possible, and the limit device should be adjusted to the specified position according to the design requirements, so that the piping system has environmental protectionFull compensation capacity.

 

7. All moving components of the compensator must not be stuck by external components or limit their range of movement, and normal movements of all moving parts should be guaranteed.

 

8. During the hydrostatic test, the secondary fixed pipe frame equipped with the compensator pipe end should be reinforced so that the pipe does not move or rotate.For the compensator used for gas medium and its connecting pipeline, pay attention to whether it is necessary to add a temporary support when filling with water.The 96 chloride ion content of the water-washing liquid for the hydrostatic test does not exceed 25 PPM.

 

9. After the hydrostatic test is over, the accumulated water in the wave shell should be drained as soon as possible, and the inner surface of the wave shell should be dried quickly.

 

10. The insulation material in contact with the compensator bellows should be chlorine-free.

 

Parameters

 

   
DN Waves MPa
0.25 0.6 1.0 1.6 2.5
Lengthmm Angular compensationmm/(Degree) StiffnessN.m/ (Degree)
150 4 600/±6.1/12 600/±5.0/23 600/±4.3/36 600/±3.4/76 600/±3.0/87
200 600/±8.9/23 600/±6.4/50 650/±5.1/115 650/±4.3/115 700/±3.5/278
250 600/±6.8/36 600/±4.9/79 650/±3.6/200 650/±3.3/320 700/±3.9/489
300 650/±7.2/36 650/±4.9/109 650/±4.0/278 750/±3.5/488 750/±3.2/594
350 650/±7.0/49 650/±3.9/109 700/±3.3/314 750/±2.8/765 800/±2.7/832
400 650/±5.5/78 660/±4.2/123 700/±3.5/502 750/±2.6/987 850/±3.0/1186
450 750/±5.0/98 750/±3.4/293 750/±2.9/754 850/±2.9/1675 1000/±2.2/1312
500 750/±5.1/121 750/±3.3/469 750/±2.2/987 850/±1.9/1532 1000/±2.3/2145
600 850/±6.1/187 850/±4.4/399 900/±3.2/1869 1000/±2.9/1150 1100/±2.0/2254
700 850/±5.9/187 850/±4.2/577 950/±3.8/768 1100/±3.0/1507
800 900/±5.5/455 900/±3.4/764 1000/±3.9/1665 1100/±2.6/2987
900 900/±4.9/364 900/±3.3/1054 1100/±3.8/1562 1200/±2.2/3398
1000 1000/±5.1/948 1000/±3.2/2020 1100/±2.9/5648 1200/±2.5/5064
1100 1000/±4.2/765 1000/±3.1/2525 1100/±2.8/4589 1300/±2.6/7356
1200 1000/±4.1/769 1000/±2.8/3386 1200/±3.1/9870 1400/±2.9/7598
1400 1100/±3.1/1336 1100/±2.2/5648 1200/±2.2/16630
1500 1100/±3.9/1864 1100/±2.1/6489 1300/±2.5/13353    

 